We support mission‑critical environments where power quality, thermal management, and automation uptime directly impact model training, inference SLAs, and colocation revenue.
-
Custom UL 508A control panels for power distribution, UPS/battery systems, generator interfaces, and critical load management.
-
BMS/DCIM integration for chilled water plants, CRAH/CRAC units, evaporative cooling, and liquid cooling loops tied into your DCIM/BMS protocols (BACnet, Modbus, OPC, SNMP).
-
Safety and monitoring systems including arc flash mitigation support, emergency power off (EPO) coordination, fire alarm interface, leak detection, and environmental monitoring.
-
Energy & demand control for battery energy storage systems (BESS), peak shaving, demand response, and generator load management to support AI workloads with volatile power profiles.
-
Retrofits, expansions, and standardization across multi‑site portfolios to align with owner engineering standards and accelerate commissioning.
Our controls work spans electrical rooms, white space, and utility interface points:
-
Main and tie breaker control and interlocking
-
ATS and generator auto‑start/transfer logic
-
UPS and battery room monitoring and alarming
-
Power distribution monitoring (mains, feeders, PDUs, RPPs)
-
Load shedding and priority load schemes for AI racks
-
Chiller plant sequencing and optimization
-
Pump VFD control and differential pressure reset
-
CRAH/CRAC unit control and redundancy strategies
-
Liquid cooling loop controls (cold plates, manifolds, leak detection)
-
Free cooling and economizer strategies
-
EPO system coordination and hardwired safety logic
-
Fire alarm and gas suppression system interfaces
-
Arc flash risk reduction strategies via remote racking/control
-
Environmental monitoring (temperature, humidity, dew point, water detection)
-
Access control and CCTV integration points for operations
-
Standardized points lists and naming conventions aligned to DCIM
-
Historian and data logging for capacity planning and AI load profiling
-
Alarm routing to NOC/SOC and ticketing systems
-
Cybersecurity hardening aligned with owner IT/OT policies
-
UL 508A certified panel fabrication with rigorous documentation and traceability for audits, insurance, and commissioning.
-
Deep cross‑industry experience in energy management, medical, automotive, and industrial automation applied to data center reliability.
-
Engineering‑led collaboration from concept through FAT/SAT, with as‑builts, point lists, and sequence of operations (SOO) clearly defined.
-
Scalable, standards‑based designs that support multi‑site rollouts and faster commissioning of new halls or AI clusters.
We integrate into your delivery model as an extension of your engineering and construction teams:
-
Define requirements & standards
-
Owner’s Project Requirements (OPR), Basis of Design (BOD), and control narratives
-
Preferred vendors, protocols, and cybersecurity standards
-
Design & engineering
-
Single‑line diagrams, I/O lists, control philosophies, panel layouts
-
Coordination with MEP, IT/OT, and commissioning agents
-
Fabrication & testing
-
UL 508A–compliant panel build, internal QA, and factory acceptance testing (FAT)appliedgraymatter
-
Software simulation and HMI/SCADA configuration
-
Installation support & commissioning
-
Site installation review, functional testing, and SAT support
-
Training for operations and handover documentation
-
Hyperscale & colocation facilities needing standardized power and cooling control packages across regions
-
AI training campuses with high‑density racks, liquid cooling, and BESS integration
-
Edge data centers requiring compact, pre‑engineered control solutions for rapid deployment
-
Retrofits & capacity upgrades where existing BMS/DCIM must integrate with new electrical and cooling systems
If you’re planning a new data/AI center, expanding capacity, or standardizing controls across sites, our team can align with your schedule and standards to deliver UL 508A–certified control solutions that reduce risk and speed commissioning.